Packaged Air Conditioning System (PAC-series)
EXPERIMENTAL CAPABILITIES
Familiarization with Package Air Conditioning System.
Analyzing the components function.
Analyzing the Cooling Tower effect.
Determination Compressor input power.
Determination degree of superheats in the Evaporator and suction line.
Determination degree of desuperheat in the discharge line.
Determination degree of sub-cooled in the Condenser and liquid line.
Determination of the Coefficient of Performance.
Plotting refrigeration cycle into Pressure Enthalpy Diagram.
Determination heat rejection in the Condenser (Qc).
Determination Refrigerating Effect (qe) and Refrigerating Capacity (Qe).
Investigating of the system malfunction based on electrical circuit.
Investigating of the system malfunction based on refrigeration circuit.
OPTIONAL MODELS:
PAC-AA-27K
Air Cooled Package Air Conditioning System
Components include:
Compressor, Forced air Condenser, Filter Drier, Thermostatic Expansion Valve (external equalizer), Forced Air Evaporator, 3 Sight Glasses with moisture indicator, 2 Manual Valves, 2 Access Valves, 3 Low Pressure Gauge (Bourdon type), 3 High Pressure Gauge (Bourdon type), Low Pressure Control, High Pressure Control, Thermostat, Temperature Display with 9 selectable thermocouple sensors, Electrical Switchboard with Voltmeter and Amperemeter. Unit protected by Earth Leakage Circuit Breaker.
PAC-WA-27K
Water Cooled Package Air Conditioning System
Components include:
Compressor, Water Cooled Condenser, Filter Drier, Thermostatic Expansion Valve (external equalizer), Forced Air Evaporator, 3 Sight Glasses with moisture indicator, 2 Manual Valves, 2 Access Valves, 3 Low Pressure Gauge (Bourdon type), 3 High Pressure Gauge (Bourdon type), Cooling Tower, Condenser Water Pump, Condenser Water Flowmeter, 2 Water Pressure Gauges, Water Flow Control, Low Pressure Control, High Pressure Control, Thermostat, Temperature Display with 9 selectable thermocouple sensors, Electrical Switchboard with Voltmeter and Amperemeter. Unit protected by Earth Leakage Circuit Breaker.
PAC-AW-27K
Air Cooled Chilled Water Package Air Conditioning System
Components include:
Compressor, Forced air Condenser, Filter Drier, Thermostatic Expansion Valve (external equalizer), Water Chiller, 3 Sight Glasses with moisture indicator, 2 Manual Valves, 2 Access Valves, 3 Low Pressure Gauge (Bourdon type), 3 High Pressure Gauge (Bourdon type), Chilled Water Pump, Fan Coil Unit, Chilled Water Flowmeter, 2 Water Pressure Gauges, Water Flow Control, Water Solenoid Valve, Closed Bleeder Expansion Tank, Air Vent Valve, Low Pressure Control, High Pressure Control, Thermostat, Temperature Display with 9 selectable thermocouple sensors, Electrical Switchboard with Voltmeter and Amperemeter. Unit protected by Earth Leakage Circuit Breaker.
PAC-WW-27K
Water Cooled Chilled Water Package Air Conditioning System
Components include:
Compressor, Water Cooled Condenser, Filter Drier, Thermostatic Expansion Valve (external equalizer), Water Chiller, 3 Sight Glasses with moisture indicator, 2 Manual Valves, 2 Access Valves, 3 Low Pressure Gauge (Bourdon type), 3 High Pressure Gauge (Bourdon type), Chilled Water Pump, Fan Coil Unit, Chilled Water Flowmeter, 4 Water Pressure Gauges, 2 Water Flow Controls, Water Solenoid Valve, Closed Bleeder Expansion Tank, Air Vent Valve, Cooling Tower, Condenser Water Pump, Condenser Water Flowmeter, Low Pressure Control, High Pressure Control, Thermostat, Temperature Display with 9 selectable thermocouple sensors, Electrical Switchboard with Voltmeter and Amperemeter. Unit protected by Earth Leakage Circuit Breaker.
OPTIONAL FAULT SIMULATORS
1. PAC-27K-F11 11 Electrical Fault Simulators
2. PAC-27K-F17 17 Electrical Fault Simulators
POWER REQUIREMENT
Three Phase, 380~415VAC, 50 Hertz
EXPERIMENT MANUAL AND JOB SHEET
The experiment manual and job sheets available in English Version or Bahasa Indonesia (depend on your request).
ORDERING INFORMATION
Select Optional Models
If required select the Optional Fault Simulators